Understanding Receiver Multicoupler and R.F. Preselectors
By: William F. Lieske, Sr.Founder, EMR Corporation
Download PDF
Table of Contents
General
The EMR corporation series of receiver multicouplers include a basic chassis on which a high performance, low noise amplifier and its power supply are mounted. A preselector is placed between the receiving antenna and the amplifier input according to the band of operation desired. The amplifier feeds a system of signal power dividers. A wide selection of preselectors, amplifiers and dividers provide multicoupler models meeting requirements of all radio site applications. Standard and custom models include:
- Operation in all popular land mobile radio bands from 30 through 960 MHz.
- Operation of from two to sixty-four receivers from a suitable antenna.
- Operation from a variety of power sources, including 117 volts or 230 volts, 50 -60 Hz., 12, 24, or 48 volts D.C., positive or negative grounded.
- Preselector passbands from as narrow as 0.5 MHz. to more than 20 MHz. according to specific site equipment requirements.
- โTower Topperโ models, having the preselector and amplifier mounted at antenna level of the tower, providing improved noise figure in system receiving, overcoming the loss in long transmission lines and other benefits.
Figure 1. Block diagram of a standard Receiver Multicoupler
Operating Theory
Figure 1 shows a block diagram of the layout of a basic receiver multicoupler system. The transmission line from the system receiving antenna connects to the input of the preselector. Preselector output is routed to a high performance amplifier, the output of which feeds the signal power divider. A high quality regulated and filtered power supply, inverter and converter supplies operating power for the amplifier. Characteristics of each of the components of the multicoupler are as follows:
Preselector
The preselector is basically a bandpass filter. Its purpose is to pass the desired range of frequencies of the receiv- ers to be employed with as near a flat response as possible and as low an insertion loss as possible. At the same time, rejection of all other frequencies is provided. EMR corporation preselectors vary from single or dual cavity resonator combinations to multi-stage inductive, aperature coupled or comb filters. Special preselector assemblies may include one or more of these devices in combination, multiple pass and stop band characteristics, special notch elements, etc. according to the complexity of site requirements. EMR preselectors are designed with optimization of losses, selectivity and costs with respect to the particular site requirements. All EMR Corporation preselectors are custom tuned and optimized using swept signal analysis techniques. They are in general very frequency stable over wide ranges of temperature, humidity, vibration and other environment conditions.
Amplifiers
The amplifiers used are of the highest quality and dependability to be found in the land mobile equipment market. Standard land mobile system amplifiers for the 30 – 50, 72 – 76, 132 – 174, 406 – 512 and 800 through 960 MHz. ranges have gains of from 15 to 26 dB, noise figures from 1.8 to 3.5 dB, 3rd order intercept rating of up to +38 dBm and 1dB compression points of up to +26 dBm. The choice of amplifier to be used in a given multicoupler is determined by frequency band, bandwidth, nature of the installed location and other relative factors. Most amplifi- ers are optimized for best noise figure and linearity at a fixed gain. Coaxial T-Pads are used to attenuate excess gain according to number of power division splits and other considerations.
Power Dividers
The power dividers split the amplifier output power into discrete matched impedance receiver feeds. The hybrid designs used in the power dividing process also provides 25 dB or more of isolation between all receivers fed by common multicoupler. Each time that the signal power is split, 3 dB of loss results plus connector and internal line losses of 0.1 to 0.2 dB. Splitting and dividing losses are generally as follows:
No. of Outputs |
No. of Splits |
Insertion Loss |
2 |
1 |
3.2 dB max |
4 |
2 |
6.4 dB max. |
8 |
3 |
9.6 dB max. |
16 |
4 |
12.9 dB max. |
32 |
5 |
16.1 dB max. |
64 |
6 |
19.5 dB max. |
Dividers for 6, 10, 12 and 36 feeds are also available. Their insertion loss is the same as the next higher number in the table above. Unused ports of any power divider must be terminated by a matching 50 ohm load to maintain balance throughout the divider โchainโ. Essentially, power dividers are hybrids employing Wilkinson Splitter or equivalent discrete component circuitry. Various combinations of splitters may be employed according to the total number of receivers to be fed and the physical site requirements in terms of cabling, rack position, etc. For ex- ample, if up to eight receivers is to be the maximum number used, a single eight-way divider would be mounted directly on the main amplifier chassis to provide the smallest rack space usage. Where 16 channels or more are involved, a two-way divider is mounted on the main chassis and eight-way dividers are mounted central to banks of receivers to reduce the total number of cable runs and cable lengths. This allows a single cable to feed groups of four, eight or twelve receivers according to their locations at the site. For example, a four-way divider mounted on the main chassis may feed four eight-way dividers mounted on sub- panels near their respective receivers. This approach saves long multiple cable runs and considerable costs in cabling. It also minimizes undesirable cable signal and noise coupling. All power dividers are supplied with BNC (female) connectors as standard. Type N or UHF connectors are avail- able on special order. The use of UHF (PL-258, SO-239) connectors is not recommended since UHF Connectors are not a constant impedance devices at frequencies above 30 MHz. All receiver feed cables should be high quality double shielded or solid outer conductor type. EMR recommends flexible double shielded cable such as RG223/U or solid copper outer conductor โSuperflexโ. Properly terminated crimp or clamp type male connectors should be used and inter-type adaptors should be avoided wherever possible.
Power Supplies
The following standard EMR receive multicoupler power supplies are available:
Model |
Description |
Power Source |
Output |
02001 |
Standard |
115 VAC @ 60 Hz. |
13.6 VDC @ 0.3 A. |
02002 |
European |
115/230 VAC @ 50-60 Hz. |
13.6 VDC @ 0.8 A. |
02003 |
Battery Powered |
12 VDC |
13.6 VDC @ 0.6 A. |
02004 |
Battery Powered |
24 VDC |
13.6 VDC @ 0.6 A. |
02005 |
Battery Powered |
48 VDC |
13.6 VDC @ 0.6 A. |
02006 |
Variable, Hi-Pwr. |
115/230 Vac @ 50-60 Hz. |
13.6 VDC @ 0.3 A. |
Figure 2, Diagram of a โTower Topperโ Receive Multicoupling System
All battery models use a self-regulating inverter for full 20 VDC output where maximum amplifier performance is required and may be operated from either positive ground battery banks. Special power supply designs are available including non-interruptable power sources operating from AC power with gelatin cells or nickel-cadmium batteries. These devices operate with an automatic float charging circuit and will deliver up to 8 hours of multicoupler operation after AC line failure.
EMR โTower Topperโ Receive Multicoupler
On-site tests of EMR Corporation โTower Topperโ multicoupler systems have verified improvements in receiver performance from as much as 4 dB to as much as 9 dB in measured effective sensitivity, and a dramatic improve- ment in range as compared to a multicoupler of identical characteristics ground mounted in traditional applications. In general, the longer the feed line, the more dramatic the improvement in performance. Several factors contribute to this measurable improvement:
- The preservation of effective noise figure that is otherwise reduced dB for dB by line loss.
- As the amplification is all in the tower top amplifier, the level of signals conducted down the transmission line is from 16 to 26 dB higher than any signal or noise responses coupled to the line.
- More accurate overall matching is maintained between the antenna and first stage amplifier, thus establishing best noise figure for the entire system.
The EMR Corporation โTower Topperโ series of receiver multicouplers were designed specifically for multiple land mobile fixed receivers that are operated at high density remote communications sites. Through the use of low loss, steep skirt response, band pass preselector filters and high performance amplifiers located as close as possible to the system receive antenna, the best possible balance between receiver noise figure and signal amplification is enjoyed. Sufficient amplifier gain is provided to overcome transmission line and splitting losses to yield exceptional performance of from two to sixty four receivers per multicoupler system. Standard models are available for receivers operating in the 132-174, 406-512 and 806-960 MHz bands, and units for the 30-50, 66-88 MHz and other bands are available on special order. Models serving any two of the standard bands using dual preselector/amplifier sections with cross-band couplers (to minimize transmission line costs) are also available.
The tower top unit is assembled in an all weather heavy gauge steel NEMA type enclosure with rubber gasketed access door. This cabinet houses the preselector, amplifier and a D.C. line tap. High quality coax cable connects to gasketed N type bulkhead connectors mounted in the bottom of the enclosure which in turn connect to the receive antenna and the coaxial โdownlineโ. The NEMA cabinet is typically held to the tower leg by heavy duty โUโ bolts supplied by EMR to suit tower leg or other mounting arrangements.
The preselector/filters feature grounded loop input and output resonator sections for lightning spike protection. Through critical coupling between resonator stages a passband having less than 0.5 dB ripple is defined over the desired receiving frequency range. A relatively steep response is provided to discriminate against out-of-band transmitter signal and noise. In some cases trap elements are provided to reject certain known frequencies, such as the paired transmitter frequencies associated with fixed relay receivers. Passband of from 1 to more than 15 MHz., according to operating band, with skirt slopes falling off at from 5 to 20 dB per MHz. above and below the desired passband range are available.
The D.C. line tap, or D.C. Block, is a device that permits carrying the amplifier supply voltage up the coaxial line with capacitative R.F. coupling and accurate impedances matching. Through the use of MOVโs (Metal Oxide Varistors), special Zener diodes and other components, the line taps provide protection to the amplifier and other components from damage due to lightning strike and also filter out other spike and noise interferences. In the equipment building, another D.C. line tap, the amplifier-power supply and divider panels, as required, are mounted on standard relay rack chassis. Power dividers are located in such a way as to minimize multiple cable runs. Unused power divider ports should always be terminated with 1/2 watt 50 Ohm loads (EMR model 1605) to maintain balance between divider sections.
The power dividers provide 25 dB of isolation between receiver feed ports for protection against receiver injection frequency leakage or possible intermodulation products generated in receiver input stages under high signal level conditions.
General Operation
The following points are of interest in the general operation of EMR Corporation Receiver Multicouplers:
Adjustments
Generally, no adjustment to any of the components of the multicoupler are required at the time of installation nor should any be attempted. Preselector pass and reject response is set to itโs optimum at the factory using wave analysis techniques. Amplifier gain is fixed and, where required, padded to optimize performance in terms of system noise figure, overall gain, etc. for best available receiver performances.
Antenna System
The antenna used to feed the multicoupler must have sufficient bandwidth for the range of frequencies involved. The receive antenna should also have sufficient physical displacement from all transmitting antennas to prevent amplifier overload or coupling of wide-band transmitter noise into the multicoupler passband range. At least 50 dB and preferably 65 dB or more of isolation between the receiving and ANY transmit antenna should be present. With certain frequency combinations even greater antenna isolations may be required. When using a duplexer, isola- tions of 65 dB or more are required to reject transmitter carrier power and wide-band noise within receiver pass- band where receivers and transmitters operate on a common antenna. Similar dynamics of isolation apply to receivers and transmitters in multiplex applications.
Cabling
Receiving antenna feedline should be routed separate from transmit feedlines. The lines should be as far away as possible from each other; on opposite tower legs, exiting the equipment building from different places, etc. No coaxial cable provides infinite outer conductor shielding and any mismatch of antenna and line will result in outer conductor standing waves and signal radiation.
Unused Ports
As stated previously, any unused power divider port should be terminated with a resistive load so that the best balance is maintained in gain levels between all receivers. EMR Corporation supplies model 1605 1/2 watt, 50 Ohm, BNC load terminations for this purpose.
Expansion
Most EMR multicouplers can be expanded to feed additional receivers. Up to a total of 64 receivers with frequen- cies falling within the preselector pass-band may be included with the addition of power divider sub-panels, the removal or replacement of existing pads and the possible change-over of amplifier and power supply. Contact EMR for assistance in ordering multicoupler expansion kits.
Interference Analysis
If interference to any receiver is experienced, any port of the divider system can be used as a โwindowโ for spec- trum analysis. A spectrum analyzer can be used to identify the source of interference, eg: excessive undesired transmitter carrier or noise coupling, intermodulation response attributable to two or more transmitters or on- channel interference from other nearby sites. EMR Corporation is pleased to help in identifying the cause and the methods of elimination of interference.
Operating Spares
All receivers in a system are dependent on the common elements of the multicoupler. While it is often impractical to maintain on-site spares of expensive radio system components, it is often advisable to keep on-site spares of the more delicate, yet vital links in the system chain. Specifically, in a multicoupling system, the amplifier and power supply are most susceptible to unexpected and unavoidable damage. EMR has designed as many safeguards as possible into our multicopling systems and we have experienced very few system failures. Those we have seen are usually due to lightning strike or remote line surge. We therefore strongly recommend that at least an amplifier and a power supply be held on-site as spares. This relatively small investment helps insure a quick repair and a short down time for your system should unexpected failure occur.